| lassification | Floatless Level Switch Relay | |||||
| Specification Model | AFR-1 | AFS-GR | PM61F-GR | 61F-GP-N | 61F-G | |
| Dimension (mm) | 61H × 49W × 70D | 50H × 40W × 58D | 50H × 40W × 58D | 50H × 40W × 70D | 79.5H × 84W × 127D | |
| Socket Type | PS-08 PF-083A(E) | PF083A(E) | PF083A(E) | PF113A(E) | - | |
| Sensing Mode | General | AFR-1 | - | - | - | 61F-G | 
| High Sensing | AFR-1H | - | - | - | - | |
| Long Distance | AFR-1L | - | - | - | - | |
| Low Density | AFR-1D | - | - | - | - | |
| Two Lines | AFR-1R | AFS-GR | PM61F-GR | 61F-GP-N | - | |
| Rated Voltage | AC: 110V, 220V, 240 50/60Hz | |||||
| Indicator Operating | Two LED's use for two status | |||||
| Operate Voltage | 85~110% of rated voltage | |||||
| Second Voltage | 8VAC (except high sensing 24VAC) | |||||
| Operate Resistance | 4K Ωmin.(GENERAL) | |||||
| Release Resistance | 15K Ωmin.(GENERAL) | |||||
| Response Time | Operate: 80msec max, Release: 160 msec max. | |||||
| Contact Rating | 5A, 250VAC(RESISTIVE LOAD) | |||||
| Length of Cable | 1Km max.(GENERAL) | |||||
| Life | Mechanical | 5 × 106 times min | ||||
| Electrical | 105 times min | |||||
| Insulation Resistance | 100MΩ (DC 500V)min | |||||
| Dielectric Strength | 1500VAC, 50/60Hz, for 1 minute | |||||
| Consumed Power | 3.2VA | |||||
| Ambient Temperature | -10oC~+55oC | |||||
| Ambient Humidity | 45~85%RH | |||||
| Weight | 200g | 150g | 150g | 150g | 380g | |